Datasheet

2012 Microchip Technology Inc. Preliminary DS41639A-page 375
PIC16(L)F1454/5/9
FIGURE 29-12: USART SYNCHRONOUS TRANSMISSION (MASTER/SLAVE) TIMING
TABLE 29-10: USART SYNCHRONOUS TRANSMISSION REQUIREMENTS
FIGURE 29-13: USART SYNCHRONOUS RECEIVE (MASTER/SLAVE) TIMING
TABLE 29-11: USART SYNCHRONOUS RECEIVE REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C TA +125°C
Param.
No.
Symbol Characteristic Min. Max. Units Conditions
US120 TCKH2DTV SYNC XMIT (Master and Slave)
Clock high to data-out valid
3.0-5.5V 80 ns
1.8-5.5V 100 ns
US121 T
CKRF Clock out rise time and fall time
(Master mode)
3.0-5.5V 45 ns
1.8-5.5V 50 ns
US122 T
DTRF Data-out rise time and fall time 3.0-5.5V 45 ns
1.8-5.5V 50 ns
Standard Operating Conditions (unless otherwise stated)
Operating Temperature -40°C TA +125°C
Param.
No.
Symbol Characteristic Min. Max. Units Conditions
US125 TDTV2CKL SYNC RCV (Master and Slave)
Data-hold before CK (DT hold time) 10 ns
US126 T
CKL2DTL Data-hold after CK (DT hold time) 15 ns
Note: Refer to Figure 29-4 for load conditions.
US121
US121
US120
US122
CK
DT
Note: Refer to Figure 29-4 for load conditions.
US125
US126
CK
DT