Datasheet

1998-2013 Microchip Technology Inc. Preliminary DS35008C-page 89
PIC16C62B/72A
13.4.2 TIMING CONDITIONS
The temperature and voltages specified in Table 13-1
apply to all timing specifications unless otherwise
noted. Figure 13-4 specifies the load conditions for the
timing specifications.
TABLE 13-1: TEMPERATURE AND VOLTAGE SPECIFICATIONS - AC
FIGURE 13-4: LOAD CONDITIONS FOR DEVICE TIMING SPECIFICATIONS
AC CHARACTERISTICS Standard Operating Conditions (unless otherwise stated)
Operating temperature 0°C T
A +70°C for commercial
-40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Operating voltage V
DD range as described in DC spec Section 13.1 and Section 13.2.
LC parts operate for commercial/industrial temps only.
VDD/2
C
L
RL
Pin
Pin
VSS
VSS
CL
RL =464
C
L = 50 pF for all pins except OSC2/CLKOUT
15 pF for OSC2 output
Load condition 1
Load condition 2