Datasheet
PIC16C62B/72A
1998-2013 Microchip Technology Inc. Preliminary DS35008C-page 53
9.2 Selecting the A/D Conversion Clock
The A/D conversion time per bit is defined as TAD. The
A/D conversion requires 9.5T
AD per 8-bit conversion.
The source of the A/D conversion clock is software
selectable. The four possible options for TAD are:
•2T
OSC
•8TOSC
•32TOSC
• Internal RC oscillator
For correct A/D conversions, the A/D conversion clock
(T
AD) must be selected to ensure a minimum TAD time
of 1.6 s.
The A/D module can operate during sleep mode, but
the RC oscillator must be selected as the A/D clock
source prior to the SLEEP instruction.
Table 9-1 shows the resultant T
AD times derived from
the device operating frequencies and the A/D clock
source selected.
9.3 Configuring Analog Port Pins
The ADCON1 and TRISA registers control the opera-
tion of the A/D port pins. The port pins that are desired
as analog inputs must have their corresponding TRIS
bits set (input). If the TRIS bit is cleared (output), the
digital output level (V
OH or VOL) will be converted.
The A/D operation is independent of the state of the
CHS2:CHS0 bits and the TRIS bits.
TABLE 9-1 TAD vs. DEVICE OPERATING FREQUENCIES
Note 1: When reading the port register, all pins
configured as analog input channels will
read as cleared (a low level). Pins config-
ured as digital inputs, will convert an ana-
log input. Analog levels on a digitally
configured input will not affect the conver-
sion accuracy.
Note 2: Analog levels on any pin that is defined as
a digital input (including the AN4:AN0
pins) may cause the input buffer to con-
sume current that is out of the devices
specification.
AD Clock Source (TAD) Device Frequency
Operation ADCS1:ADCS0 20 MHz 5 MHz 1.25 MHz 333.33 kHz
2T
OSC 00
100 ns
(2)
400 ns
(2)
1.6 s6 s
8TOSC 01
400 ns
(2)
1.6 s6.4 s
24 s
(3)
32TOSC 10 1.6 s6.4 s
25.6 s
(3)
96 s
(3)
RC
(5)
11
2 - 6 s
(1,4)
2 - 6 s
(1,4)
2 - 6 s
(1,4)
2 - 6 s
(1)
Legend: Shaded cells are outside of recommended range.
Note 1: The RC source has a typical T
AD time of 4 s.
2: These values violate the minimum required T
AD time.
3: For faster conversion times, the selection of another clock source is recommended.
4: When device frequency is greater than 1 MHz, the RC A/D conversion clock source is recommended for
sleep operation only.