Datasheet
PIC16C6X
DS30234E-page 222 1997-2013 Microchip Technology Inc.
Applicable Devices 61 62 62A R62 63 R63 64 64A R64 65 65A R65 66 67
FIGURE 19-7: PARALLEL SLAVE PORT TIMING
TABLE 19-7: PARALLEL SLAVE PORT REQUIREMENTS
Parameter
No.
Sym Characteristic Min Typ† Max Units Conditions
62
TdtV2wrH Data in valid before WR
or CS (setup time) 20 — — ns
63* TwrH2dtI WR
or CS to data–in invalid (hold
time)
PIC16C65 20 — — ns
PIC16LC65 35 — — ns
64 TrdL2dtV RD
and CS to data–out valid — — 80 ns
65 TrdH2dtI RD
or CS to data–out invalid 10 — 30 ns
* These parameters are characterized but not tested.
† Data in "Typ" column is at 5V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note: Refer to Figure 19-1 for load conditions
RE2/CS
RE0/RD
RE1/WR
RD7:RD0
62
63
64
65