4.2.2.6 PCON Register
The PCON register contains flag bits to differentiate
between a Power-on Reset, an external MCLR
Reset,
WDT Reset or a Brown-out Reset.
REGISTER 4-6: PCON REGISTER (ADDRESS 8Eh)
Note: BOR is unknown on Power-on Reset. It
must then be set by the user and checked
on subsequent RESETS to see if BOR
is
cleared, indicating a brown-out has
occurred. The BOR
STATUS bit is a "don't
care" and is not necessarily predictable if
the brown-out circuit is disabled (by
programming BODEN bit in the
Configuration word).
U-0 U-0 U-0 U-0 U-0 U-0 R/W-0 R/W-0
— — — — — —PORBOR
bit 7 bit 0
bit 7-2 Unimplemented: Read as '0'
bit 1 POR
: Power-on Reset STATUS bit
1 = No Power-on Reset occurred
0 = A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
bit 0 BOR
: Brown-out Reset STATUS bit
1 = No Brown-out Reset occurred
0 = A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs)
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
- n = Value at POR ’1’ = Bit is set ’0’ = Bit is cleared x = Bit is unknown