Datasheet

PIC16C5X
DS30453E-page 88 Preliminary 1997-2013 Microchip Technology Inc.
FIGURE 13-3: CLKOUT AND I/O TIMING - PIC16CR54A
TABLE 13-2: CLKOUT AND I/O TIMING REQUIREMENTS - PIC16CR54A
AC Characteristics
Standard Operating Conditions (unless otherwise specified)
Operating Temperature 0°C T
A +70C for commercial
–40C T
A +85C for industrial
–40C T
A +125C for extended
Param
No.
Symbol Characteristic Min Typ† Max Units
10 TosH2ckL OSC1 to CLKOUT
(1)
—1530**ns
11 TosH2ckH OSC1 to CLKOUT
(1)
—1530**ns
12 TckR CLKOUT rise time
(1)
—5.015**ns
13 TckF CLKOUT fall time
(1)
—5.015**ns
14 TckL2ioV CLKOUT to Port out valid
(1)
——40**ns
15 TioV2ckH Port in valid before CLKOUT
(1)
0.25 TCY+30* ns
16 TckH2ioI Port in hold after CLKOUT
(1)
0* ns
17 TosH2ioV OSC1 (Q1 cycle) to Port out valid
(2)
100* ns
18 TosH2ioI OSC1 (Q2 cycle) to Port input invalid
(I/O in hold time)
TBD ns
19 TioV2osH Port input valid to OSC1
(I/O in setup time)
TBD ns
20 TioR
Port output rise time
(2)
—1025**ns
21 TioF
Port output fall time
(2)
—1025**ns
* These parameters are characterized but not tested.
** These parameters are design targets and are not tested. No characterization data available at this time.
Data in the Typical (“Typ”) column is based on characterization results at 25C. This data is for design guid-
ance only and is not tested.
Note 1: Measurements are taken in RC Mode where CLKOUT output is 4 x T
OSC.
2: Please refer to Figure 13.1 for load conditions.
OSC1
CLKOUT
I/O Pin
(input)
I/O Pin
(output)
Q4
Q1
Q2 Q3
10
14
17
20, 21
18
15
11
16
Old Value
New Value
19
12
13
Note: Please refer to Figure 13.1 for load conditions.