Datasheet

1999-2012 Microchip Technology Inc. DS40192D-page 61
PIC16C505
Output High Voltage
D090 I/O ports/CLKOUT (Note 3) V
OH VDD - 0.7
——
VIOH = -3.0 mA, VDD = 4.5V,
–40C to +85C
D090A VDD - 0.7
——
VIOH = -2.5 mA, VDD = 4.5V,
–40C to +125C
D092 OSC2 VDD - 0.7
——
VIOH = -1.3 mA, VDD = 4.5V,
–40C to +85C
D092A V
DD - 0.7
——
VIOH = -1.0 mA, VDD = 4.5V,
–40C to +125C
Capacitive Loading Specs on
Output Pins
D100 OSC2 pin COSC2
——
15 pF In XT, HS and LP modes when
external clock is used to drive
OSC1.
D101 All I/O pins and OSC2 C
IO
——
50 pF
DC CHARACTERISTICS
Standard Operating Conditions (unless otherwise specified)
Operating temperature 0°C T
A +70°C (commercial)
–40°C T
A +85°C (industrial)
–40°C T
A +125°C (extended)
Operating voltage V
DD range as described in DC spec Section 10.1 and
Section 10.3.
Param
No.
Characteristic Sym Min Typ† Max Units Conditions
Data in “Typ” column is at 5V, 25C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note 1: In EXTRC oscillator configuration, the OSC1/CLKIN pin is a Schmitt Trigger input. It is not recommended that the PIC16C505
be driven with external clock in RC mode.
2: The leakage current on the MCLR
pin is strongly dependent on the applied voltage level. The specified levels represent nor-
mal operating conditions. Higher leakage current may be measured at different input voltages.
3: Negative current is defined as coming out of the pin.
4: Does not include GP3. For GP3 see parameters D061 and D061A.
5: This spec. applies to GP3/MCLR
configured as external MCLR and GP3/MCLR configured as input with internal pull-up
enabled.
6: This spec. applies when GP3/MCLR
is configured as an input with pull-up disabled. The leakage current of the MCLR circuit
is higher than the standard I/O logic.