Datasheet
PIC12F752/HV752
DS41576B-page 180 Preliminary 2011 Microchip Technology Inc.
20.11 AC Characteristics: PIC12F752/HV752 (Industrial, Extended)
FIGURE 20-4: CLOCK TIMING
TABLE 20-1: CLOCK OSCILLATOR TIMING REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +125°C
Param
No.
Sym Characteristic Min Typ† Max Units Conditions
OS01
F
OSC External CLKIN Frequency
(1)
DC — 20 MHz EC Oscillator mode
OS02
T
OSC External CLKIN Period
(1)
50 — ns EC Oscillator mode
OS03
T
CY Instruction Cycle Time
(1)
200 TCY DC ns TCY = 4/FOSC
* These parameters are characterized but not tested.
† Data in “Typ” column is at 5V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
Note 1: Instruction cycle period (T
CY) equals four times the input oscillator time base period. All specified values are based on
characterization data for that particular oscillator type under standard operating conditions with the device executing
code. Exceeding these specified limits may result in an unstable oscillator operation and/or higher than expected current
consumption. All devices are tested to operate at “min” values with an external clock applied to CLKIN pin. When an
external clock input is used, the “max” cycle time limit is “DC” (no clock) for all devices.
CLKIN
CLKOUT
Q4 Q1 Q2 Q3 Q4 Q1
OS02
OS03
OS04 OS04
CLKOUT
(CLKOUT Mode)