Datasheet

MCP73213
DS22190B-page 2 © 2009 Microchip Technology Inc.
Typical Application
TABLE 1: AVAILABLE FACTORY PRESET OPTIONS
TABLE 2: STANDARD SAMPLE OPTIONS
Charge
Voltage
OVP
Pre-
conditioning
Charge Current
Pre-
conditioning
Threshold
Precondition
Timer
Elapse
Timer
End-of-
Charge
Control
Automatic
Recharge
Output
Status
8.2V 13V Disable / 10% 66.5% / 71.5% Disable /
32 Minimum
Disable / 4 HR /
6 HR / 8 HR
5% / 7.5% /
10% / 20%
No /
Yes
Type 1 /
Type 2
8.4V 13V Disable / 10% 66.5% / 71.5% Disable /
32 Minimum
Disable / 4 HR /
6 HR / 8 HR
5% / 7.5% /
10% / 20%
No /
Yes
Type 1 /
Type 2
8.7V 13V Disable / 10% 66.5% / 71.5% Disable /
32 Minimum
Disable / 4 HR /
6 HR / 8 HR
5% / 7.5% /
10% / 20%
No /
Yes
Type 1 /
Type 2
8.8V 13V Disable / 10% 66.5% / 71.5% Disable /
32 Minimum
Disable / 4 HR /
6 HR / 8 HR
5% / 7.5% /
10% / 20%
No /
Yes
Type 1 /
Type 2
Note 1: I
REG
: Regulated fast charge current.
2: V
REG
: Regulated charge voltage.
3: I
PREG
/I
REG
: Preconditioning charge current; ratio of regulated fast charge current.
4: I
TERM
/I
REG
: End-of-Charge control; ratio of regulated fast charge current.
5: V
RTH
/V
REG
: Recharge threshold; ratio of regulated battery voltage.
6: V
PTH
/V
REG
: Preconditioning threshold voltage.
Part
Number
V
REG
OVP I
PREG
/I
REG
Pre-charge
Timer
Elapse
Timer
I
TERM
/I
REG
V
RTH
/V
REG
V
PTH
/V
REG
Output
Status
MCP73213-B6S/MF 8.20V 13V 10% 32 Min. 6 HR 10% 95% 71.5% Type 1
MCP73213-A6S/MF 8.40V 13V 10% 32 Min. 6 HR 10% 95% 71.5% Type 1
Note 1: Customers should contact their distributor, representatives or field application engineer (FAE) for support and sample.
Local sales offices are also available to help customers. A listing of sales offices and locations is included in the back of
this document. Technical support is available through the web site at: http//support.microchip.com
V
DD
5
3
1
2
8
7
R
PROG
9
10
C
IN
C
OUT
R
LED
+
-
2-Cell
Li-Ion
Battery
6
4
MCP73213 Typical Application
V
DD
STAT
NC
NC
V
BAT
V
BAT
PROG
V
SS
V
SS
Ac-dc-Adapter