Datasheet

© 2010 Microchip Technology Inc. DS22187E-page 9
MCP4728
SCL Rise Time
(Note 1)
T
RSCL
1000 ns Standard Mode
20 + 0.1Cb 300 ns Fast Mode
20 80 ns High Speed Mode 1.7
20 160 ns High Speed Mode 1.7
(Note 2)
10 40 ns High Speed Mode 3.4
10 80 ns High Speed Mode 3.4
(Note 2)
SDA Rise Time
(Note 1)
T
RSDA
1000 ns Standard Mode
20 + 0.1Cb 300 ns Fast Mode
20 80 ns High Speed Mode 1.7
10 40 ns High Speed Mode 3.4
SCL Fall Time
(Note 1)
T
FSCL
300 ns Standard Mode
20 + 0.1Cb 300 ns Fast Mode
20 80 ns High Speed Mode 1.7
10 40 ns High Speed Mode 3.4
SDA Fall Time
(Note 1)
T
FSDA
300 ns Standard Mode
20 + 0.1Cb 300 ns Fast Mode
20 160 ns High Speed Mode 1.7
10 80 ns High Speed Mode 3.4
Data Input Setup Time
T
SU:DAT
250 ns Standard Mode
100 ns Fast Mode
10 ns High Speed Mode 1.7
10 ns High Speed Mode 3.4
Data Hold Time
(Input, Output)
(Note 3)
T
HD:DAT
0 3450 ns Standard Mode
0 900 ns Fast Mode
0 150 ns High Speed Mode 1.7
0 70 ns High Speed Mode 3.4
Output Valid from Clock
(Note 4)
T
AA
0 3750 ns Standard Mode
0 1200 ns Fast Mode
0 310 ns High Speed Mode 1.7
0 150 ns High Speed Mode 3.4
I
2
C SERIAL TIMING SPECIFICATIONS (CONTINUED)
Electrical Specifications: Unless otherwise specified, all limits are specified for T
A
= -40 to +125°C, V
SS
= 0V,
Standard and Fast Mode: V
DD
= +2.7V to +5.5V
High Speed Mode: V
DD
= +4.5V to +5.5V.
Parameters Sym Min Typ Max Units Conditions
Note 1:
This parameter is ensured by characterization and is not 100% tested.
2: After a Repeated Start condition or an Acknowledge bit.
3: If this parameter is too short, it can create an unintentional Start or Stop condition to other devices on the I
2
C bus line. If
this parameter is too long, the Data Input Setup (T
SU:DAT
) or Clock Low time (T
LOW
) can be affected.
Data Input: This parameter must be longer than t
SP
.
Data Output: This parameter is characterized, and tested indirectly by testing T
AA
parameter.
4: This specification is not a part of the I
2
C specification. This specification is equivalent to the Data Hold Time (T
HD:DAT
)
plus SDA Fall (or rise) time: T
AA
= T
HD:DAT
+ T
FSDA
(OR T
RSDA
).
5: Time between Start and Stop conditions.