Datasheet

2008-2013 Microchip Technology Inc. DS22107B-page 13
MCP454X/456X/464X/466X
FIGURE 1-1: I
2
C Bus Start/Stop Bits Timing Waveforms.
TABLE 1-1: I
2
C BUS START/STOP BITS REQUIREMENTS
I
2
C AC Characteristics
Standard Operating Conditions (unless otherwise specified)
Operating Temperature –40C T
A +125C (Extended)
Operating Voltage V
DD range is described in AC/DC characteristics
Param.
No.
Symbol Characteristic Min Max Units Conditions
F
SCL
Standard mode 0 100 kHz C
b
= 400 pF, 1.8V - 5.5V
Fast mode 0 400 kHz C
b
= 400 pF, 2.7V - 5.5V
High-Speed 1.7 0 1.7 MHz C
b
= 400 pF, 4.5V - 5.5V
High-Speed 3.4 0 3.4 MHz C
b
= 100 pF, 4.5V - 5.5V
D102 Cb Bus capacitive
loading
100 kHz mode 400 pF
400 kHz mode 400 pF
1.7 MHz mode 400 pF
3.4 MHz mode 100 pF
90 T
SU:STA START condition 100 kHz mode 4700 ns Only relevant for repeated
START condition
Setup time 400 kHz mode 600 ns
1.7 MHz mode 160 ns
3.4 MHz mode 160 ns
91 T
HD:STA START condition 100 kHz mode 4000 ns After this period the first
clock pulse is generated
Hold time 400 kHz mode 600 ns
1.7 MHz mode 160 ns
3.4 MHz mode 160 ns
92 T
SU:STO STOP condition 100 kHz mode 4000 ns
Setup time 400 kHz mode 600 ns
1.7 MHz mode 160 ns
3.4 MHz mode 160 ns
93 T
HD:STO STOP condition 100 kHz mode 4000 ns
Hold time 400 kHz mode 600 ns
1.7 MHz mode 160 ns
3.4 MHz mode 160 ns
91
93
SCL
SDA
START
Condition
STOP
Condition
90
92