Datasheet
MCP2510
DS21291F-page 24 © 2007 Microchip Technology Inc.
REGISTER 4-1: RXB0CTRL - RECEIVE BUFFER 0 CONTROL REGISTER
(ADDRESS: 60h)
U-0 R/W-0 R/W-0 U-0 R-0 R/W-0 R-0 R-0
— RXM1 RXM0 — RXRTR BUKT BUKT1 FILHIT0
bit 7 bit 0
bit 7 Unimplemented: Read as '0'
bit 6-5 RXM<1:0>: Receive Buffer Operating Mode
11 =Turn mask/filters off; receive any message
10 =Receive only valid messages with extended identifiers that meet filter criteria
01 =Receive only valid messages with standard identifiers that meet filter criteria
00 =Receive all valid messages using either standard or extended identifiers that meet filter
criteria
bit 4 Unimplemented: Read as '0'
bit 3 RXRTR: Received Remote Transfer Request
1 = Remote Transfer Request Received
0 = No Remote Transfer Request Received
bit 2 BUKT: Rollover Enable
1 = RXB0 message will rollover and be written to RXB1 if RXB0 is full
0 = Rollover disabled
bit 1 BUKT1: Read Only Copy of BUKT Bit (used internally by the MCP2510).
bit 0 FILHIT<0>: Filter Hit - indicates which acceptance filter enabled reception of message
1 = Acceptance Filter 1 (RXF1)
0 = Acceptance Filter 0 (RXF0)
Note: If a rollover from RXB0 to RXB1 occurs, the FILHIT bit will reflect the filter that accepted
the message that rolled over
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ’1’ = Bit is set ’0’ = Bit is cleared x = Bit is unknown