Information
Installation and Operation
© 2009 Microchip Technology Inc. DS51842A-page 17
TABLE 2-2: MCP2122 AND MCP2120 BAUD RATE SELECTION
MODE
PWM
Frequency
MCP2122
Baud
MCP2120
Baud
Comment
73 2:0
X1
1 1 1 1,843,200 115,200 Note 1 Designed for use with MCP2122 only
1 1 0 921,600 57,600 Note 1 Designed for use with MCP2122 only
1 0 1 460,800 28,800 Note 1 Designed for use with MCP2122 only
1 0 0 — Reserved Note 1 Designed for use with MCP2122 only
0 1 1 — Reserved Note 1 Designed for use with MCP2122 only
0 1 0 614,400 38,400 Note 1 Designed for use with MCP2122 only
0 0 1 307,200 19,200 Note 1 Designed for use with MCP2122 only
0 0 0 153,600 9,600 Note 1 Designed for use with MCP2122 only
10
1 1 1
3.6864 MHz
230,400
(Note 3)
Reserved
1 1 0 57,600 MCP2120’s BAUD2:0 pins = “1 0 0”.
1 0 1 Reserved
1 0 0 Reserved
0 1 1 Reserved
0 1 0 38,400 MCP2120’s BAUD2:0 pins = “0 1 0”.
0 0 1 19,200 MCP2120’s BAUD2:0 pins = “0 0 1”.
0 0 0 9,600 MCP2120’s BAUD2:0 pins = “0 0 0“.
00
1 1 1
0MHz Note 4
115,200 MCP2120’s BAUD2:0 pins = “1 0 0“. (Note 2)
1 1 0 57,600 MCP2120’s BAUD2:0 pins = “0 1 1“. (Note 2)
1 0 1 Reserved
1 0 0 Reserved
0 1 1 Reserved
0 1 0 38,400 MCP2120’s BAUD2:0 pins = “0 1 0“. (Note 2)
0 0 1 19,200 MCP2120’s BAUD2:0 pins = “0 0 1“. (Note 2)
0 0 0 9,600 MCP2120’s BAUD2:0 pins = “0 0 0“. (Note 2)
Legend:X = Undefined (either "1" or "0").
Note 1: Baud rate would be dependant on the state of the MCP2120’s BAUD2:0 pins.
2: A 7.3728 MHz external crystal must be used.
3: This exceeds the device’s maximum specification.
4: The MCP2122 16XCLK signal is static.