Datasheet
MCP19111
DS22331A-page 40 2013 Microchip Technology Inc.
6.5 Voltage for Zero Current
In multi-phase systems it may be necessary to provide
some offset to the sensed inductor current. The
VZCCON register can be used to provide a positive or
negative offset in the sensed current. Typically, the
VZCCON will be set to 0x80h, which corresponds to
the sensed inductor current centered around 1.45V.
However, by adjusting the VZCCON register, this
centered voltage can be shifted up or down by
approximately 3.28 mV per step.
REGISTER 6-5: VZCCON: VOLTAGE FOR ZERO CURRENT CONTROL REGISTER
R/W-x R/W-x R/W-x R/W-x R/W-x R/W-x R/W-x R/W-x
VZC7 VZC6 VZC5 VZC4 VZC3 VZC2 VZC1 VZC0
bit 7 bit 0
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 7-0 VZC<7:0>: Voltage for Zero Current Setting bits
00000000 = -420.00 mV Offset
00000001 = -416.72 mV Offset
•
•
•
10000000 = 0 mV Offset
•
•
•
11111110 = +413.12 mV Offset
11111111 = +416.40 mV Offset