6.5 Pulsed Load Applications
For some applications, there are pulsed load current
events that may exceed the specified 250 mA
maximum specification of the MCP1703A. The internal
current limit of the MCP1703A prevents high peak load
demands from causing non-recoverable damage. The
250 mA rating is a maximum average continuous
rating. As long as the average current does not exceed
250 mA, pulsed higher load currents can be applied to
the MCP1703A
. The typical current limit for the
MCP1703A is 500 mA (T
A
= +25°C).