2.3.1.5.3 How the MCP1631HV Digitally Controlled Programmable Current Source
Reference Design Operates in Charger Mode
Follow the instructions in Section 2.3.1.5.1 “How to Connect and Charge a Battery
with the MCP1631HV Digitally Controlled Programmable Current Source
Reference Design” to connect a battery pack at the board. In the Standby (OFF) state,
the GREEN LED will be lit. Push the S1 button to start the charge profile and turn on
the output. The GREEN LED will flash.
If any fault conditions are detected during charging, the RED LED will flash and the
output will automatically turn off. See Table 2-1 to identify the nature of the fault. When
a charge cycle successfully completes, the GREEN LED will be turned ON and the
output will be turned off. The system will stay in a Standby (OFF) state until the next
button push.
At any moment, the charging can be stopped by pressing and holding the push button
until the RED LED turns on.
The default calibration value for the Li-Ion pack is 4.2V. For better accuracy, the output
voltage should be calibrated before starting a charge cycle. See
Section 2.3.1.5.4 “Calibrating the Output Voltage for the Li-Ion Chemistry Profile”
for instructions.
2.3.1.5.4 Calibrating the Output Voltage for the Li-Ion Chemistry Profile
Prior to the first Li-Ion charging cycle, it is recommended to calibrate the charger
termination voltage for better accuracy. Connect a 12V
power supply to the J1
connector. Select another power supply for the calibration voltage and set it to the
desired termination voltage between 3.9V and 4.20V. Connect the calibration power
supply to the J2 connector. Connect the positive lead to J2-1 and the negative lead to
J2-5.
1. Press S1 to turn on the board.
2. Wait for the GREEN LED to light. If it does not light, check for faults.
3. When the GREEN LED is lit, press and hold down S1 for 2 seconds until the
YELLOW LED (both green and red LEDs) is lit. The YELLOW status indicator
signals the calibration is complete.
4. The calibration power supply can now be removed from the J2 output connector.