Datasheet

dsPIC33FJ06GS101/X02 and dsPIC33FJ16GSX02/X04
DS70000318G-page 258 2008-2014 Microchip Technology Inc.
bit 12-8 TRGSRC5<4:0>: Trigger 5 Source Selection bits
Selects trigger source for conversion of Analog Channels AN11 and AN10.
11111 = Timer2 period match
11011 = Reserved
11010 = PWM Generator 4 current-limit ADC trigger
11001 = PWM Generator 3 current-limit ADC trigger
11000 = PWM Generator 2 current-limit ADC trigger
10111 = PWM Generator 1 current-limit ADC trigger
10110 = Reserved
10010 = Reserved
10001 = PWM Generator 4 secondary trigger is selected
10000 = PWM Generator 3 secondary trigger is selected
01111 = PWM Generator 2 secondary trigger is selected
01110 = PWM Generator 1 secondary trigger is selected
01101 = Reserved
01100 = Timer1 period match
01000 = Reserved
00111 = PWM Generator 4 primary trigger is selected
00110 = PWM Generator 3 primary trigger is selected
00101 = PWM Generator 2 primary trigger is selected
00100 = PWM Generator 1 primary trigger is selected
00011 = PWM Special Event Trigger is selected
00010 = Global software trigger is selected
00001 = Individual software trigger is selected
00000 = No conversion is enabled
bit 7 IRQEN4: Interrupt Request Enable 4 bit
1 = Enables IRQ generation when requested conversion of Channels AN9 and AN8 is completed
0 = IRQ is not generated
bit 6 PEND4: Pending Conversion Status 4 bit
1 = Conversion of Channels AN9 and AN8 is pending; set when selected trigger is asserted
0 = Conversion is complete
bit 5 SWTRG4: Software Trigger 4 bit
1 = Starts conversion of AN9 and AN8 (if selected by the TRGSRCx bits)
(2)
This bit is automatically cleared by hardware when the PEND4 bit is set.
0 = Conversion has not started
REGISTER 19-7: ADCPC2: ANALOG-TO-DIGITAL CONVERT PAIR
CONTROL REGISTER 2
(1)
(CONTINUED)
Note 1: This register is only implemented in the dsPIC33FJ16GS504 devices.
2: The trigger source must be set as a global software trigger prior to setting this bit to ‘1’. If other conversions
are in progress, then the conversion will be performed when the conversion resources are available.