Datasheet

dsPIC33F
DS70165E-page 330 Preliminary © 2007 Microchip Technology Inc.
FIGURE 26-14: SPIx MODULE MASTER MODE (CKE = 0) TIMING CHARACTERISTICS
TABLE 26-31: SPIx MASTER MODE (CKE = 0) TIMING REQUIREMENTS
SCKx
(CKP = 0)
SCKx
(CKP = 1)
SDOx
SDIx
SP11 SP10
SP40
SP41
SP21
SP20
SP35
SP20
SP21
MSb LSb
Bit 14 - - - - - -1
MSb In
LSb In
Bit 14 - - - -1
SP30
SP31
Note: Refer to Figure 26-1 for load conditions.
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C
Param
No.
Symbol Characteristic
(1)
Min Typ
(2)
Max Units Conditions
SP10 TscL SCKx Output Low Time
(3)
TCY/2 ns
SP11 TscH SCKx Output High Time
(3)
TCY/2 ns
SP20 TscF SCKx Output Fall Time
(4)
ns See parameter D032
SP21 TscR SCKx Output Rise Time
(4)
ns See parameter D031
SP30 TdoF SDOx Data Output Fall Time
(4)
ns See parameter D032
SP31 TdoR SDOx Data Output Rise Time
(4)
ns See parameter D031
SP35 TscH2doV,
TscL2doV
SDOx Data Output Valid after
SCKx Edge
30 ns
SP40 TdiV2scH,
TdiV2scL
Setup Time of SDIx Data Input
to SCKx Edge
20 ns
SP41 TscH2diL,
TscL2diL
Hold Time of SDIx Data Input
to SCKx Edge
20 ns
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance only and
are not tested.
3: The minimum clock period for SCKx is 100 ns. Therefore, the clock generated in Master mode must not
violate this specification.
4: Assumes 50 pF load on all SPIx pins.