Datasheet
© 2007 Microchip Technology Inc. Preliminary DS70165E-page 327
dsPIC33F
FIGURE 26-10: MOTOR CONTROL PWM MODULE FAULT TIMING CHARACTERISTICS
FIGURE 26-11: MOTOR CONTROL PWM MODULE TIMING CHARACTERISTICS
TABLE 26-28: MOTOR CONTROL PWM MODULE TIMING REQUIREMENTS
FLTA/B
PWMx
MP30
MP20
PWMx
MP11
MP10
Note: Refer to Figure 26-1 for load conditions.
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C
Param
No.
Symbol Characteristic
(1)
Min Typ
(2)
Max Units Conditions
MP10 T
FPWM PWM Output Fall Time — — — ns See parameter D032
MP11 TRPWM PWM Output Rise Time — — — ns See parameter D031
MP20
T
FD Fault Input ↓ to PWM
I/O Change
——50ns —
MP30 T
FH Minimum Pulse Width 50 — — ns —
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance only and
are not tested.