Datasheet

© 2008 Microchip Technology Inc. DS01208A-page 11
AN1208
FIGURE 9: INSTALL FEEDBACK
CURRENT SELECTION
RESISTORS
4. Remove the LK2 jumper connection and place a
link on jumper LK1.
5. Place jumper LK4 in the 1-2 position.
6. Place jumpers on link LK5 through LK12.
System Execution Procedure
Complete the following steps to execute the integrated
PFC and Sensorless FOC algorithm that controls the
motor:
1. Launch the MPLAB software and open the
program.
2. Run the algorithm.
3. Apply AC input voltage to the dsPICDEM MC1H
High Voltage Power module.
4. Make sure VR2, the Speed Reference POT, is in
its minimum position and VR1, the Initial Torque
Reference POT, is set between the 0% and 25%
position.
5. Start the motor by pressing the S4 switch.
The motor starts in Open Loop mode and ramps
up the speed until it is equal to 900 rpm, and
then makes a transition from Open Loop mode
to Closed Loop mode.
6. When the motor enters Closed Loop mode and
stabilizes, start the PFC calculations by pressing
the S7 switch.
The DC bus voltage boosts from its initial value
based on the amplitude of the applied AC input
voltage.
7. Change values of the VR2 POT to operate the
motor at a different speed.
8. Stop the motor by pressing the S4 switch.
To obtain feedback current, the circuit links must
be completed.
To activate the current feedback for this
application, populate links LK20, LK21, and LK31
with 5.6 kΩ resistors.
LK20, LK21, and LK31 Links
5.6 kΩ Shunt Resistors
BEFORE
AFTER