Datasheet
Table Of Contents
- Small Footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support
- 1.0 Introduction
- 2.0 Pin Description and Configuration
- 3.0 Functional Description
- 3.1 Transceiver
- 3.2 Auto-negotiation
- 3.3 HP Auto-MDIX Support
- 3.4 MAC Interface
- 3.5 Serial Management Interface (SMI)
- 3.6 Interrupt Management
- 3.7 Configuration Straps
- 3.8 Miscellaneous Functions
- 3.9 Application Diagrams
- 4.0 Register Descriptions
- 4.1 Register Nomenclature
- 4.2 Control and Status Registers
- TABLE 4-2: SMI Register Map
- 4.2.1 Basic Control Register
- 4.2.2 Basic Status Register
- 4.2.3 PHY Identifier 1 Register
- 4.2.4 PHY Identifier 2 Register
- 4.2.5 Auto Negotiation Advertisement Register
- 4.2.6 Auto Negotiation Link Partner Ability Register
- 4.2.7 Auto Negotiation Expansion Register
- 4.2.8 Mode Control/Status Register
- 4.2.9 Special Modes Register
- 4.2.10 Symbol Error Counter Register
- 4.2.11 Special Control/Status Indications Register
- 4.2.12 Interrupt Source Flag Register
- 4.2.13 Interrupt Mask Register
- 4.2.14 PHY Special Control/Status Register
- 5.0 Operational Characteristics
- 6.0 Package Information
- 7.0 Application Notes
- Appendix A: Data Sheet Revision History
- The Microchip Web Site
- Customer Change Notification Service
- Customer Support
- Product Identification System
- Worldwide Sales and Service

2016 Microchip Technology Inc. DS00002165B-page 57
LAN8720A/LAN8720AI
Note 5-17 Measured differentially.
TABLE 5-6: 10BASE-T TRANSCEIVER CHARACTERISTICS
Parameter Symbol Min Typ Max Units Notes
Transmitter Peak Differential Output Voltage V
OUT
2.2 2.5 2.8 V Note 5-15
Receiver Differential Squelch Threshold V
DS
300 420 585 mV —
Note 5-18 Min/
max voltages guaranteed as measured with 100 resistive load.
5.5 AC Specifications
This section details the various AC timing specifications of the device.
Note 5-19 The
SMI timing adheres to the IEEE 802.3 specification. Refer to the IEEE 802.3 specification for
additional timing information.
Note 5-20 The RMI
I timing adheres to the RMII Consortium RMII Specification R1.2.
5.5.1 EQUIVALENT TEST LOAD
Output timing specifications assume a 25pF equivalent test load, unless otherwise noted, as illustrated in Figure 5-1
below.
FIGURE 5-1: OUTPUT EQUIVALENT TEST LOAD
25 pF
OUTPUT