Datasheet

±15kV ESD Protected MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support and flexPWR
®
Technology in a Small Footprint
Datasheet
SMSC LAN8700/LAN8700i 59 Revision 2.3 (04-12-11)
DATASHEET
6.2.1.2 100M MII Transmit Timing
Figure 6.3 100M MII Transmit Timing Diagram
Table 6.3 100M MII Transmit Timing Values
PARAMETER DESCRIPTION MIN TYP MAX UNITS NOTES
T3.1 Transmit signals required setup to
TX_CLK rising
12 ns
Transmit signals required hold
after TX_CLK rising
0ns
TX_CLK frequency 25 MHz
TX_CLK Duty-Cycle 40 %
Clock Out -
TX_CLK
Data Out -
TXD[3:0]
T
3.1
TX_EN
TX_ER
Valid Data