Datasheet
Table Of Contents
- 1.0 Introduction
- 2.0 Pin Description and Configuration
- 3.0 Functional Description- 3.1 10BASE-T/100BASE-TX Transceiver
- 3.2 RMII Interface
- 3.3 Back-to-Back Mode – 100 Mbps Copper Repeater
- 3.4 MII Management (MIIM) Interface
- 3.5 Interrupt (INTRP)
- 3.6 HP Auto MDI/MDI-X
- 3.7 Loopback Mode
- 3.8 LinkMD® Cable Diagnostic
- 3.9 NAND Tree Support
- 3.10 Power Management
- 3.11 Reference Circuit for Power and Ground Connections
- 3.12 Typical Current/Power Consumption
 
- 4.0 Register Descriptions
- 5.0 Operational Characteristics
- 6.0 Electrical Characteristics
- 7.0 Timing Diagrams
- 8.0 Reset Circuit
- 9.0 Reference Circuits — LED Strap-In Pins
- 10.0 Reference Clock - Connection and Selection
- 11.0 Magnetic - Connection and Selection
- 12.0 Package Outline

KSZ8081RNA/RND
DS00002199A-page 32    2016 Microchip Technology Inc.
1B.8 Link-Up 
Interrupt 
Enable
1 = Enable link-up interrupt
0 = Disable link-up interrupt
RW 0
1B.7 Jabber Inter-
rupt
1 = Jabber occurred
0 = Jabber did not occur
RO/SC 0
1B.6 Receive 
Error Inter-
rupt
1 = Receive error occurred
0 = Receive error did not occur
RO/SC 0
1B.5 Page 
Receive 
Interrupt
1 = Page receive occurred
0 = Page receive did not occur
RO/SC 0
1B.4 Parallel 
Detect Fault 
Interrupt
1 = Parallel detect fault occurred
0 = Parallel detect fault did not occur
RO/SC 0
1B.3 Link Partner 
Acknowl-
edge Inter-
rupt
1 = Link partner acknowledge occurred
0 = Link partner acknowledge did not occur
RO/SC 0
1B.2 Link-Down 
Interrupt
1 = Link-down occurred
0 = Link-down did not occur
RO/SC 0
1B.1 Remote Fault 
Interrupt
1 = Remote fault occurred
0 = Remote fault did not occur
RO/SC 0
1B.0 Link-Up 
Interrupt
1 = Link-up occurred
0 = Link-up did not occur
RO/SC 0
Register 1Dh – LinkMD Control/Status
1D.15 Cable Diag-
nostic Test 
Enable
1 = Enable cable diagnostic test. After test has 
completed, this bit is self-cleared.
0 = Indicates cable diagnostic test (if enabled) has 
completed and the status information is valid for 
read.
RW/SC 0
1D.14:13 Cable Diag-
nostic Test 
Result
[00] = Normal condition
[01] = Open condition has been detected in cable
[10] = Short condition has been detected in cable
[11] = Cable diagnostic test has failed
RO 00
1D.12 Short Cable 
Indicator
1 = Short cable (<10 meter) has been detected by 
LinkMD
RO 0
1D.11:9 Reserved Reserved RW 000
1D.8:0 Cable Fault 
Counter
Distance to fault RO 0_0000_0000
Register 1Eh – PHY Control 1
1E.15:10 Reserved Reserved RO 0000_00
1E.9 Enable 
Pause (Flow 
Control)
1 = Flow control capable
0 = No flow control capability
RO 0
1E.8 Link Status 1 = Link is up
0 = Link is down
RO 0
1E.7 Polarity Sta-
tus
1 = Polarity is reversed
0 = Polarity is not reversed
RO
1E.6 Reserved Reserved RO 0
TABLE 4-2: REGISTER DESCRIPTIONS (CONTINUED)
Address Name Description
Mode
Note 4-1
Default