TABLE 30-33: I2Cx BUS DATA TIMING REQUIREMENTS (SLAVE MODE)
AC CHARACTERISTICS
Standard Operating Conditions: 2.3V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
-40°C T
A +105°C for V-temp
Param.
No.
Symbol Characteristics Min. Max. Units Conditions
IS10 T
LO:SCL Clock Low Time 100 kHz mode 4.7 s PBCLK must operate at a
minimum of 800 kHz
400 kHz mode 1.3 s PBCLK must operate at a
minimum of 3.2 MHz
1 MHz mode
(Note 1)
0.5 s—
IS11 T
HI:SCL Clock High Time 100 kHz mode 4.0 s PBCLK must operate at a
minimum of 800 kHz
400 kHz mode 0.6 s PBCLK must operate at a
minimum of 3.2 MHz
1 MHz mode
(Note 1)
0.5 s—
IS20 T
F:SCL SDAx and SCLx
Fall Time
100 kHz mode 300 ns CB is specified to be from
10 to 400 pF
400 kHz mode 20 + 0.1 CB 300 ns
1 MHz mode
(Note 1)
100 ns
IS21 T
R:SCL SDAx and SCLx
Rise Time
100 kHz mode 1000 ns CB is specified to be from
10 to 400 pF
400 kHz mode 20 + 0.1 CB 300 ns
1 MHz mode
(Note 1)
300 ns
IS25 T
SU:DAT Data Input
Setup Time
100 kHz mode 250 ns
400 kHz mode 100 ns
1 MHz mode
(Note 1)
100 ns
IS26 THD:DAT Data Input
Hold Time
100 kHz mode 0 ns
400 kHz mode 0 0.9 s
1 MHz mode
(Note 1)
00.3s
IS30 T
SU:STA Start Condition
Setup Time
100 kHz mode 4700 ns Only relevant for Repeated
Start condition
400 kHz mode 600 ns
1 MHz mode
(Note 1)
250 ns
IS31 T
HD:STA Start Condition
Hold Time
100 kHz mode 4000 ns After this period, the first
clock pulse is generated
400 kHz mode 600 ns
1 MHz mode
(Note 1)
250 ns
IS33 T
SU:STO Stop Condition
Setup Time
100 kHz mode 4000 ns
400 kHz mode 600 ns
1 MHz mode
(Note 1)
600 ns
Note 1: Maximum pin capacitance = 10 pF for all I2Cx pins (for 1 MHz mode only).