User manual
PICkit™ Serial Analyzer User’s Guide
DS51647A-page 82 © 2007 Microchip Technology Inc.
TABLE 9-14: COMM SCRIPT STATUS BLOCK
9.6 I
2
CM COMMUNICATIONS
I
2
CM refers to the Master mode of the I
2
C protocol. See the I
2
C specification for proto-
col details. In this mode, the PICkit™ Serial Analyzer will master the I
2
C bus only. It will
not respond as a slave. The control block of memory dedicated to communication
allows for setting of the bit rate and displaying event markers in the software windows.
TABLE 9-15: CONNECTOR PINOUT IN I
2
CM MODE
Byte Bit Description
COMM: GENERAL
4 7:0 COMM status: error
0 Time-out AB0
1 Time-out AB1
2 COMM initialization error
3 VSRC fault
4 Data error (e.g., unrecognized TAG, missing data, etc.)
5 Output buffer overrun (CBUF2)
6 Output buffer overrun (CBUF3)
7 Composite error
5 7:0 COMM status: informational
0 Controller busy
1 Executing MACRO
2 Executing MACRO – infinite loop
3Executing WAIT instruction
4
5
6
7 “End-of-Script” TAG encountered
6 7:0 COMM mode
7 7:0 VSRC Measurement (0-255)
87:0
97:0
10 7:0
11 7:0
Pin Description
1—
2+V
3GND
4SDA
5SCL
6—