8.2.2 Keys
MPLAB PM3 provides four keys for navigation. The function of each key is:
<ESC> – return to the previous menu or entry.
<Up> – moves the selection bar up one line each time it is pressed.
<Down> – moves the selection bar down one line each time it is pressed.
<Enter> – performs the selected function.
8.3 START-UP SEQUENCE
When power is applied to the MPLAB PM3 programmer, it initiates a start-up sequence.
The system performs a self-check, briefly displays the splash screen, then the
versions, followed by the MPLAB PM3 Main menu. If you do not get to the Main menu,
see Appendix B. “Troubleshooting”.
Once the start-up sequence has completed, you will see the Main menu:
8.4 MAIN MENU
The Main menu gives you these options:
Recently Used
Select Device
Programmer Settings
•Help
8.4.1 Recently Used
To display the most recently used devices:
1. Select (highlight) the “Recently Used” option and press <Enter>. Up to seven of
the most recently used devices are listed.
2. To continue using this device, press <Enter>.
3. The system displays the Command menu. See Section 8.5 “Command Menu”.
8.4.2 Select Device
To select a specific device, you must:
1. Select (highlight) the “Select Device” option and press <Enter>.
2. Select the device family and press <Enter>.
3. Select the device and press <Enter>.
4. The system displays the Command menu. See Section 8.5 “Command Menu”.
8.4.3 Programmer Settings
From the Programmer Settings option on the Main menu, you can access:
Screen Contrast
•Buzzer Volume
Socket Information
Checksum Calculation
Device ID Option (Beta)
Blank Check Override
Go Pin Functionality
Note: If you need to update the operating system, you will have to connect to a
PC with MPLAB IDE running to accomplish this.