B.6.5 Program Memory Contains Code-Protected Data
Program memory contains data that was read from a code-protected device. Most or
all of this data is not usable. Obtain the original hex code from a file or a non-protected
device. See also Section B.6.3 “Device is Code-Protected”.
B.6.6 Invalid Checksum
This error indicates a hardware problem occurred while trying to read from the
programmer. It is not a very common error. It usually indicates some sort of problem
with the communication hardware on either the PC or the programmer.
B.7 ERROR MESSAGES – LCD
B.7.1 BIOS Errors
TABLE B-1: MPLAB
®
PM3 BEEP CODES
Number
of Beeps
Meaning Corrective Action
1 Normal start up No action required.
2 CPLD Not Configured Reset and connect to MPLAB IDE.
3 Power Monitor Not Found Reset and connect to MPLAB IDE.
4 Display Not Found Reset the unit. If the problem persists,
contact your field representative to SAR
the unit.
5 Display Read Write Test Failure Reset the unit. If the problem persists,
contact your field representative to SAR
the unit.
6 FPGA Time-out Reset the unit. If the problem persists,
contact your field representative to SAR
the unit.