User manual

MPLAB
®
PM3 User’s Guide
DS51464C-page 102 © 2006 Microchip Technology Inc.
Information on using ICSP for a specific device is described in the device’s
programming specification. You can find programming specifications on the Microchip
web site.
A.4.2 ICSP VDD/VPP Operating Characteristics
Note: Since MPLAB PM3 has ICSP built-in, you cannot use the PRO MATE II
ICSP Socket Module (AC04004) and the MPLAB PM3-to-PRO MATE II
device adapter.
TABLE A-4: POWER VIA MPLAB
®
PM3
Parameter Value
VPP Range 9-14V in 125 mV steps
IPP Range 150 mA max
VDD Range 2-5.5V in 125 mV steps
IDD Range 500 mA max
Protection Over Voltage Shutdown
TABLE A-5: POWER VIA TARGET
Parameter Value
Ta r ge t V DD Range 2-5.5V
VPP Range 9-14V in 125 mV steps
IPP -150 mA max
Ta r ge t V DD Range 2-5.5V
Protection IPP Overcurrent Fuse, Over Voltage Shutdown
Note: The use of any cable (other material, length...) other than the one provided