Datasheet

© 2007-2012 Microchip Technology Inc. DS70291G-page 411
dsPIC33FJ32MC302/304, dsPIC33FJ64MCX02/X04 AND dsPIC33FJ128MCX02/X04
TABLE 31-56: DMA READ/WRITE TIMING REQUIREMENTS
TABLE 31-55: PARALLEL MASTER PORT WRITE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
-40°C TA +125°C for Extended
Param
No.
Characteristic Min Typ Max Units Conditions
PM11 PMWR Pulse Width 0.5 TCY —ns
PM12 Data Out Valid before PMWR or PMENB goes
Inactive (data setup time)
——ns
PM13 PMWR or PMEMB Invalid to Data Out Invalid
(data hold time)
——ns
PM16 PMCSx Pulse Width T
CY - 5 ns
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Characteristic Min Typ Max Units Conditions
DM1 DMA Read/Write Cycle Time 1 TCY ns