Datasheet
dsPIC33FJ32MC202/204 and dsPIC33FJ16MC304
DS70283K-page 254 © 2007-2012 Microchip Technology Inc.
FIGURE 24-9: OC/PWM MODULE TIMING CHARACTERISTICS
OCFA
OCx
OC20
OC15
Active
Tri-state
TABLE 24-28: SIMPLE OC/PWM MODE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ T
A ≤ +125°C for Extended
Param
No.
Symbol Characteristic
(1)
Min Typ Max Units Conditions
OC15 TFD Fault Input to PWM I/O
Change
——TCY + 20 ns —
OC20 TFLT Fault Input Pulse-Width TCY + 20 — — ns —
Note 1: These parameters are characterized but not tested in manufacturing.