Datasheet
dsPIC33FJ32MC202/204 and dsPIC33FJ16MC304
DS70283K-page 242 © 2007-2012 Microchip Technology Inc.
TABLE 24-11: ELECTRICAL CHARACTERISTICS: BOR
DC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ T
A ≤ +125°C for Extended
Param
No.
Symbol Characteristic
(1)
Min Typ Max Units Conditions
BO10 V
BOR BOR Event on VDD transition 2.40 — 2.55 V See Note 2
Note 1: Parameters are for design guidance only and are not tested in manufacturing.
2: Device is functional at V
BORMIN < VDD < VDDMIN. Analog modules such as the ADC will have degraded
performance. Device functionality is tested but not characterized.
TABLE 24-12: DC CHARACTERISTICS: PROGRAM MEMORY
DC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Symbol Characteristic
(3)
Min Typ
(1)
Max Units Conditions
Program Flash Memory
D130 E
P Cell Endurance 10,000 — — E/W -40°C to +125°C
D131 V
PR VDD for Read VMIN —3.6VVMIN = Minimum operating voltage
D132B V
PEW VDD for Self-Timed Write VMIN —3.6VVMIN = Minimum operating voltage
D134 T
RETD Characteristic Retention 20 — — Year Provided no other specifications
are violated, -40°C to +125°C
D135 I
DDP Supply Current during
Programming
—10 —mA
D136a T
RW Row Write Time 1.32 — 1.74 ms TRW = 11064 FRC cycles,
TA = +85°C, See Note 2
D136b T
RW Row Write Time 1.28 — 1.79 ms TRW = 11064 FRC cycles,
T
A = +150°C, See Note 2
D137a T
PE Page Erase Time 20.1 — 26.5 ms TPE = 168517 FRC cycles,
TA = +85°C, See Note 2
D137b T
PE Page Erase Time 19.5 — 27.3 ms TPE = 168517 FRC cycles,
T
A = +150°C, See Note 2
D138a T
WW Word Write Cycle Time 42.3 — 55.9 μsTWW = 355 FRC cycles,
T
A = +85°C, See Note 2
D138b T
WW Word Write Cycle Time 41.1 — 57.6 μsTWW = 355 FRC cycles,
TA = +150°C, See Note 2
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated.
2: Other conditions: FRC = 7.37 MHz, TUN<5:0> = b'011111 (for Min), TUN<5:0> = b'100000 (for Max).
This parameter depends on the FRC accuracy (see Table 24-18) and the value of the FRC Oscillator Tun-
ing register (see Register 8-4). For complete details on calculating the Minimum and Maximum time see
Section 5.3 “Programming Operations”.
3: These parameters are assured by design, but are not characterized or tested in manufacturing.