2009-2012 Microchip Technology Inc. DS70591E-page 121
dsPIC33FJ32GS406/606/608/610 and dsPIC33FJ64GS406/606/608/610
6.9 Using the RCON Status Bits
The user application can read the Reset Control
(RCON) register after any device Reset to determine
the cause of the Reset.
Table 6-2 provides a summary of the Reset flag bit
operation.
TABLE 6-2: RESET FLAG BIT OPERATION
Note: The status bits in the RCON register
should be cleared after they are read so
that the next RCON register value after a
device Reset will be meaningful.
Flag Bit Set by: Cleared by:
TRAPR (RCON<15>) Trap conflict event POR, BOR
IOPWR (RCON<14>) Illegal opcode or uninitialized W register
access or Security Reset
POR, BOR
EXTR (RCON<7>) MCLR
Reset POR
SWR (RCON<6>) RESET instruction POR, BOR
WDTO (RCON<4>) WDT time-out PWRSAV instruction, CLRWDT instruction,
POR, BOR
SLEEP (RCON<3>) PWRSAV #SLEEP instruction POR, BOR
IDLE (RCON<2>) PWRSAV #IDLE instruction POR, BOR
BOR (RCON<1>) POR, BOR —
POR (RCON<0>) POR —
Note: All Reset flag bits can be set or cleared by user software.