Datasheet

© 2009 Microchip Technology Inc. DS70286C-page 293
dsPIC33FJXXXGPX06/X08/X10
TABLE 25-40: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
Param
No.
Symbol Characteristic Min. Typ
(1)
Max. Units Conditions
Clock Parameters
AD50a TAD ADC Clock Period 117.6 ns
AD51a tRC ADC Internal RC Oscillator
Period
250 ns
Conversion Rate
AD55a t
CONV Conversion Time 14 TAD ns
AD56a F
CNV Throughput Rate 500 ksps
AD57a TSAMP Sample Time 3 TAD ——
Timing Parameters
AD60a t
PCS Conversion Start from Sample
Trigger
(2)
2.0 TAD 3.0 TAD Auto-Convert Trigger
(SSRC<2:0> = 111) not
selected
AD61a t
PSS Sample Start from Setting
Sample (SAMP) bit
(2)
2.0 TAD 3.0 TAD ——
AD62a t
CSS Conversion Completion to
Sample Start (ASAM = 1)
(2)
0.5 TAD ——
AD63a t
DPU Time to Stabilize Analog Stage
from ADC Off to ADC On
(2,3)
——20μs—
Note 1: These parameters are characterized but not tested in manufacturing.
2: Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity
performance, especially at elevated temperatures.
3: t
DPU is the time required for the ADC module to stabilize when it is turned on (AD1CON1<ADON> = 1).
During this time, the ADC result is indeterminate.