Datasheet

dsPIC33FJXXXGPX06/X08/X10
DS70286C-page 280 © 2009 Microchip Technology Inc.
TABLE 25-31: SPIx MODULE SLAVE MODE (CKE = 1) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C
Param
No.
Symbol Characteristic
(1)
Min Typ
(2)
Max Units Conditions
SP70 TscL SCKx Input Low Time 30 ns
SP71 TscH SCKx Input High Time 30 ns
SP72 TscF SCKx Input Fall Time
(3)
—1025ns
SP73 TscR SCKx Input Rise Time
(3)
—1025ns
SP30 TdoF SDOx Data Output Fall Time
(3)
ns See parameter D032
SP31 TdoR SDOx Data Output Rise Time
(3)
ns See parameter D031
SP35 TscH2doV,
TscL2doV
SDOx Data Output Valid after
SCKx Edge
30 ns
SP40 TdiV2scH,
TdiV2scL
Setup Time of SDIx Data Input
to SCKx Edge
20 ns
SP41 TscH2diL,
TscL2diL
Hold Time of SDIx Data Input
to SCKx Edge
20 ns
SP50 TssL2scH,
TssL2scL
SSx to SCKx or SCKx
Input
120 ns
SP51 TssH2doZ SSx
to SDOX Output
High-Impedance
(4)
10 50 ns
SP52 TscH2ssH
TscL2ssH
SSx
after SCKx Edge 1.5 TCY + 40 ns
SP60 TssL2doV SDOx Data Output Valid after
SSx Edge
50 ns
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated.
3: The minimum clock period for SCKx is 100 ns. Therefore, the clock generated in Master mode must not
violate this specification.
4: Assumes 50 pF load on all SPIx pins.