Datasheet

© 2007-2011 Microchip Technology Inc. DS70265E-page 269
dsPIC33FJ12MC201/202
TABLE 24-46: ADC CONVERSION (10-BIT MODE) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristic Min. Typ
(1)
Max. Units Conditions
Clock Parameters
(2)
AD50 TAD ADC Clock Period 76 ns
AD51 t
RC ADC Internal RC Oscillator Period 250 ns
Conversion Rate
AD55 t
CONV Conversion Time 12 TAD ——
AD56 F
CNV Throughput Rate 1.1 Msps
AD57 T
SAMP Sample Time 2.0 TAD ——— —
Timing Parameters
AD60 t
PCS Conversion Start from Sample
Trigger
(1)
2.0 TAD 3.0 TAD Auto-Convert Trigger
(SSRC<2:0> = 111) not
selected
AD61 tPSS Sample Start from Setting
Sample (SAMP) bit
(1)
2.0 TAD 3.0 TAD ——
AD62 tCSS Conversion Completion to
Sample Start (ASAM = 1)
(1)
0.5 TAD ——
AD63 t
DPU Time to Stabilize Analog Stage
from ADC Off to ADC On
(1)
——20μs—
Note 1: These parameters are characterized but not tested in manufacturing.
2: Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity
performance, especially at elevated temperatures.