Datasheet

dsPIC33FJ32MC302/304, dsPIC33FJ64MCX02/X04 AND dsPIC33FJ128MCX02/X04
DS70291G-page 404 © 2007-2012 Microchip Technology Inc.
TABLE 31-46: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C TA +125°C for Extended
Param
No.
Symbol Characteristic Min Typ Max Units Conditions
Clock Parameters
AD50 T
AD ADC Clock Period 117.6 ns
AD51 t
RC ADC Internal RC Oscillator
Period
250 ns
Conversion Rate
AD55 t
CONV Conversion Time 14 TAD ns
AD56 FCNV Throughput Rate 500 Ksps
AD57 T
SAMP Sample Time 3 TAD
Timing Parameters
AD60 t
PCS
Conversion Start from Sample
Trigger
(2)
2 TAD —3 TAD Auto convert trigger not
selected
AD61 t
PSS Sample Start from Setting
Sample (SAMP) bit
(2)
2 TAD —3 TAD ——
AD62 tCSS Conversion Completion to
Sample Start (ASAM = 1)
(2)
0.5 TAD ——
AD63 t
DPU Time to Stabilize Analog Stage
from ADC Off to ADC On
(2)
——20μs—
Note 1: Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity
performance, especially at elevated temperatures.
2: These parameters are characterized but not tested in manufacturing.
3: The t
DPU is the time required for the ADC module to stabilize at the appropriate level when the module is
turned on (AD1CON1<ADON>=‘1’). During this time, the ADC result is indeterminate.