Datasheet

dsPIC33FJ32GP302/304, dsPIC33FJ64GPX02/X04, AND dsPIC33FJ128GPX02/X04
DS70292G-page 348 © 2007-2012 Microchip Technology Inc.
TABLE 30-13: INTERNAL VOLTAGE REGULATOR SPECIFICATIONS
TABLE 30-11: ELECTRICAL CHARACTERISTICS: BOR
DC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C TA +125°C for Extended
Param
No.
Symbol Characteristic Min
(1)
Typ Max
(1)
Units Conditions
BO10
V
BOR BOR Event on VDD transition high-to-low 2.40 2.55 V VDD
Note 1: Parameters are for design guidance only and are not tested in manufacturing.
TABLE 30-12: DC CHARACTERISTICS: PROGRAM MEMORY
DC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristic Min Typ
(1)
Max Units Conditions
Program Flash Memory
D130a EP Cell Endurance 10,000 E/W -40°C to +125° C
D131 V
PR VDD for Read VMIN —3.6VVMIN = Minimum operating
voltage
D132B V
PEW VDD for Self-Timed Write VMIN —3.6VVMIN = Minimum operating
voltage
D134 T
RETD Characteristic Retention 20 Year Provided no other specifications
are violated
D135 I
DDP Supply Current during
Programming
—10 mA
D136a T
RW Row Write Time 1.32 1.74 ms TRW = 11064 FRC cycles,
T
A = +85°C, See Note 2
D136b T
RW Row Write Time 1.28 1.79 ms TRW = 11064 FRC cycles,
TA = +125°C, See Note 2
D137a T
PE Page Erase Time 20.1 26.5 ms TPE = 168517 FRC cycles,
TA = +85°C, See Note 2
D137b T
PE Page Erase Time 19.5 27.3 ms TPE = 168517 FRC cycles,
T
A = +125°C, See Note 2
D138a T
WW Word Write Cycle Time 42.3 55.9 µs TWW = 355 FRC cycles,
TA = +85°C, See Note 2
D138b T
WW Word Write Cycle Time 41.1 57.6 µs TWW = 355 FRC cycles,
TA = +125°C, See Note 2
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated.
2: Other conditions: FRC = 7.37 MHz, TUN<5:0> = b'011111 (for Min), TUN<5:0> = b'100000 (for Max).
This parameter depends on the FRC accuracy (see Table 30-19) and the value of the FRC Oscillator
Tuning register (see Register 9-4). For complete details on calculating the Minimum and Maximum time
see Section 5.3 “Programming Operations”.
Standard Operating Conditions (unless otherwise stated):
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristics Min Typ Max Units Comments
C
EFC External Filter Capacitor
Value
(1)
4.7 10 μF Capacitor must be low series
resistance (< 5 Ohms)
Note 1: Typical V
CAP voltage = 2.5V when VDD VDDMIN.