9.1 CPU Clocking System
The dsPIC33EPXXXGP50X, dsPIC33EPXXXMC20X/
50X and PIC24EPXXXGP/MC20X family of devices
provides six system clock options:
• Fast RC (FRC) Oscillator
• FRC Oscillator with Phase Locked Loop (PLL)
• FRC Oscillator with Postscaler
• Primary (XT, HS or EC) Oscillator
• Primary Oscillator with PLL
• Low-Power RC (LPRC) Oscillator
Instruction execution speed or device operating
frequency, F
CY, is given by Equation 9-1.
EQUATION 9-1: DEVICE OPERATING
FREQUENCY
Figure 9-2 is a block diagram of the PLL module.
Equation 9-2 provides the relationship between input
frequency (F
IN) and output frequency (FOSC).
Equation 9-3 provides the relationship between input
frequency (F
IN) and VCO frequency (FSYS).
FIGURE 9-2: PLL BLOCK DIAGRAM
EQUATION 9-2: F
OSC CALCULATION
EQUATION 9-3: F
VCO
CALCULATION
FCY = Fosc/2
÷ N1
÷ M
÷ N2
PFD VCO
PLLPRE<4:0>
PLLDIV<8:0>
PLLPOST<1:0>
0.8 MHz < FPLLI
(1)
< 8.0 MHz
120 MH
Z < FSYS
(1)
< 340 MHZ
FOSC
(1)
120 MHz @ +125ºC
F
IN
FPLLI FSYS FOSC
Note 1: This frequency range must be met at all times.
F
OSC
(1)
140 MHz @ +85ºC
FOSC FIN
M
N1 N2
---------------------
F
IN
PLLDIV 2+
PLLPRE 2+2 PLLPOST 1+
----------------------------------------------------------------------------------------
==
Where:
N1 = PLLPRE + 2
N2 = 2 x (PLLPOST + 1)
M = PLLDIV + 2
FSYS FIN
M
N1
-------
F
IN
PLLDIV 2+
PLLPRE 2+
-------------------------------------
==