Datasheet

dsPIC33EPXXXGP50X, dsPIC33EPXXXMC20X/50X AND PIC24EPXXXGP/MC20X
DS70657G-page 420 2011-2013 Microchip Technology Inc.
FIGURE 30-9: HIGH-SPEED PWMx MODULE FAULT TIMING CHARACTERISTICS
(dsPIC33EPXXXMC20X/50X and PIC24EPXXXMC20X DEVICES ONLY)
FIGURE 30-10: HIGH-SPEED PWMx MODULE TIMING CHARACTERISTICS
(dsPIC33EPXXXMC20X/50X and PIC24EPXXXMC20X DEVICES ONLY)
TABLE 30-29: HIGH-SPEED PWMx MODULE TIMING REQUIREMENTS
(dsPIC33EPXXXMC20X/50X and PIC24EPXXXMC20X DEVICES ONLY)
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristic
(1)
Min. Typ. Max. Units Conditions
MP10 T
FPWM PWMx Output Fall Time ns See Parameter DO32
MP11 TRPWM PWMx Output Rise Time ns See Parameter DO31
MP20 T
FD Fault Input to PWMx
I/O Change
——15ns
MP30 T
FH Fault Input Pulse Width 15 ns
Note 1: These parameters are characterized but not tested in manufacturing.
Fault Input
PWMx
MP30
MP20
(active-low)
PWMx
MP11
MP10
Note: Refer to Figure 30-1 for load conditions.