2011-2013 Microchip Technology Inc. DS70657G-page 315
dsPIC33EPXXXGP50X, dsPIC33EPXXXMC20X/50X AND PIC24EPXXXGP/MC20X
22.2 CTMU Control Registers
REGISTER 22-1: CTMUCON1: CTMU CONTROL REGISTER 1
R/W-0 U-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
CTMUEN
CTMUSIDL TGEN EDGEN EDGSEQEN IDISSEN
(1)
CTTRIG
bit 15 bit 8
U-0 U-0 U-0 U-0 U-0 U-0 U-0 U-0
bit 7 bit 0
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 15 CTMUEN: CTMU Enable bit
1 = Module is enabled
0 = Module is disabled
bit 14 Unimplemented: Read as ‘0
bit 13 CTMUSIDL: CTMU Stop in Idle Mode bit
1 = Discontinues module operation when device enters Idle mode
0 = Continues module operation in Idle mode
bit 12 TGEN: Time Generation Enable bit
1 = Enables edge delay generation
0 = Disables edge delay generation
bit 11 EDGEN: Edge Enable bit
1 = Hardware modules are used to trigger edges (TMRx, CTEDx, etc.)
0 = Software is used to trigger edges (manual set of EDGxSTAT)
bit 10 EDGSEQEN: Edge Sequence Enable bit
1 = Edge 1 event must occur before Edge 2 event can occur
0 = No edge sequence is needed
bit 9 IDISSEN: Analog Current Source Control bit
(1)
1 = Analog current source output is grounded
0 = Analog current source output is not grounded
bit 8 CTTRIG: ADC Trigger Control bit
1 = CTMU triggers ADC start of conversion
0 = CTMU does not trigger ADC start of conversion
bit 7-0 Unimplemented: Read as0
Note 1: The ADC module Sample-and-Hold capacitor is not automatically discharged between sample/conversion
cycles. Software using the ADC as part of a capacitance measurement must discharge the ADC capacitor
before conducting the measurement. The IDISSEN bit, when set to 1’, performs this function. The ADC
must be sampling while the IDISSEN bit is active to connect the discharge sink to the capacitor array.