TABLE 23-15: PLL CLOCK TIMING SPECIFICATIONS (VDD = 2.5 TO 5.5 V)
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C TA +125°C for Extended
Param
No.
Symbol Characteristic
(1)
Min Typ
(2)
Max Units Conditions
OS50 F
PLLI PLL Input Frequency Range
(2)
4
4
4
4
4
4
5
(3)
5
(3)
5
(3)
4
4
4
10
10
7.5
(4)
10
10
7.5
(4)
10
10
7.5
(4)
8.33
(3)
8.33
(3)
7.5
(4)
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
EC with 4x PLL
EC with 8x PLL
EC with 16x PLL
XT with 4x PLL
XT with 8x PLL
XT with 16x PLL
HS/2 with 4x PLL
HS/2 with 8x PLL
HS/2 with 16x PLL
HS/3 with 4x PLL
HS/3 with 8x PLL
HS/3 with 16x PLL
OS51 F
SYS On-Chip PLL Output
(2)
16 120 MHz EC, XT, HS/2, HS/3 modes
with PLL
OS52 T
LOC PLL Start-up Time (Lock Time) 20 50 μs
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance only and
are not tested.
3: Limited by oscillator frequency range.
4: Limited by device operating frequency range.
TABLE 23-16: PLL JITTER
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Characteristic Min Typ
(1)
Max Units Conditions
OS61 x4 PLL 0.251 0.413 % -40°C T
A +85°C VDD = 3.0 to 3.6V
0.251 0.413 % -40°C TA +125°C VDD = 3.0 to 3.6V
0.256 0.47 % -40°C T
A +85°C VDD = 4.5 to 5.5V
0.256 0.47 % -40°C T
A +125°C VDD = 4.5 to 5.5V
x8 PLL 0.355 0.584 % -40°C T
A +85°C VDD = 3.0 to 3.6V
0.355 0.584 % -40°C T
A +125°C VDD = 3.0 to 3.6V
0.362 0.664 % -40°C T
A +85°C VDD = 4.5 to 5.5V
0.362 0.664 % -40°C T
A +125°C VDD = 4.5 to 5.5V
x16 PLL 0.67 0.92 % -40°C T
A +85°C VDD = 3.0 to 3.6V
0.632 0.956 % -40°C T
A +85°C VDD = 4.5 to 5.5V
0.632 0.956 % -40°C T
A +125°C VDD = 4.5 to 5.5V
Note 1: These parameters are characterized but not tested in manufacturing.