Datasheet

Table Of Contents
© 2006 Microchip Technology Inc. DS70117F-page 177
dsPIC30F6011/6012/6013/6014
TABLE 23-7: DC CHARACTERISTICS: POWER-DOWN CURRENT (IPD)
DC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Parameter
No.
Typical
(1)
Max Units Conditions
Power Down Current (I
PD)
DC60a 0.3 μA 25°C
3.3V
Base Power Down Current
(2)
DC60b 2 60 μA 85°C
DC60c 23 120 μA 125°C
DC60e 0.5 μA 25°C
5VDC60f 3 110 μA 85°C
DC60g 32 180 μA 125°C
DC61a 10 20 μA 25°C
3.3V
Watchdog Timer Current: ΔI
WDT
(3)
DC61b 10 20 μA 85°C
DC61c 10 20 μA 125°C
DC61e 18 30 μA 25°C
5VDC61f 17 30 μA 85°C
DC61g 17 30 μA 125°C
DC62a 4 10 μA 25°C
3.3V
Timer 1 w/32 kHz Crystal: ΔI
TI32
(3)
DC62b 5 10 μA 85°C
DC62c 4 10 μA 125°C
DC62e 4 15 μA 25°C
5VDC62f 6 15 μA 85°C
DC62g 5 15 μA 125°C
DC63a 30 55 μA 25°C
3.3V
BOR On: ΔI
BOR
(3)
DC63b 32 55 μA 85°C
DC63c 34 55 μA 125°C
DC63e 34 60 μA 25°C
5VDC63f 37 60 μA 85°C
DC63g 38 60 μA 125°C
DC66a 18 35 μA 25°C
3.3V
Low-Voltage Detect: ΔI
LVD
(3)
DC66b 20 35 μA 85°C
DC66c 21 35 μA 125°C
DC66e 22 40 μA 25°C
5VDC66f 23 40 μA 85°C
DC66g 24 40 μA 125°C
Note 1: Data in the Typical column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance
only and are not tested.
2: Base I
PD is measured with all peripherals and clocks shut down. All I/Os are configured as inputs and
pulled high. LVD, BOR, WDT, etc. are all switched off.
3: The Δ current is the additional current consumed when the module is enabled. This current should be
added to the base I
PD current.