Datasheet

dsPIC30F6010A/6015
DS70150E-page 216 © 2011 Microchip Technology Inc.
TABLE 24-41: 10-BIT HIGH-SPEED A/D CONVERSION TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.7V to 5.5V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristic Min. Typ
(1)
Max. Units Conditions
Clock Parameters
AD50 T
AD A/D Clock Period 84 ns See Table 20-2
(2)
AD51 tRC A/D Internal RC Oscillator Period 700 900 1100 ns
Conversion Rate
AD55 t
CONV Conversion Time 12 TAD ——
AD56 F
CNV Throughput Rate 1.0 Msps See Table 20-2
(2)
AD57 TSAMP Sample Time 1 TAD See Table 20-2
(2)
Timing Parameters
AD60 t
PCS Conversion Start from Sample
Trigger
(3)
1.0 TAD Auto-Convert Trigger
(SSRC = 111) not
selected
AD61 tPSS Sample Start from Setting
Sample (SAMP) Bit
0.5 TAD 1.5 TAD ——
AD62 tCSS Conversion Completion to
Sample Start (ASAM = 1)
(3)
0.5 TAD ——
AD63 tDPU
(4)
Time to Stabilize Analog Stage
from A/D Off to A/D On
(3)
——20μs—
Note 1: These parameters are characterized but not tested in manufacturing.
2: Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity
performance, especially at elevated temperatures.
3: Characterized by design but not tested.
4: t
DPU is the time required for the ADC module to stabilize when it is turned on (ADCON1<ADON> = 1).
During this time the ADC result is indeterminate.