Datasheet
© 2011 Microchip Technology Inc. DS70150E-page 199
dsPIC30F6010A/6015
FIGURE 24-12: MOTOR CONTROL PWM MODULE FAULT TIMING CHARACTERISTICS
FIGURE 24-13: MOTOR CONTROL PWM MODULE TIMING CHARACTERISTICS
FLTA/B
PWMx
MP30
MP20
PWMx
MP11 MP10
Note: Refer to Figure 24-2 for load conditions.
TABLE 24-30: MOTOR CONTROL PWM MODULE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ T
A ≤ +125°C for Extended
Param
No.
Symbol Characteristic
(1)
Min Typ
(2)
Max Units Conditions
MP10 TFPWM PWM Output Fall Time — — — ns
See parameter DO32
MP11 T
RPWM PWM Output Rise Time — — — ns See parameter DO31
MP20
TFD Fault Input ↓ to PWM
I/O Change
——50ns —
MP30 T
FH Minimum Pulse Width 50 — — ns —
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance only and