Datasheet

dsPIC30F1010/202X
DS70178C-page 118 Preliminary © 2006 Microchip Technology Inc.
bit 6-3 FLTSRC<3:0>: Fault Control Signal Source Select for PWM Generator #X bits
0000 = Analog Comparator #1
0001 = Analog Comparator #2
0010 = Analog Comparator #3
0011 = Analog Comparator #4
0100 = Reserved
0101 = Reserved
0110 = Reserved
0111 = Reserved
1000 = Shared Fault #1 (SFLT1)
1001 = Shared Fault #2 (SFLT2)
1020 = Shared Fault #3 (SFLT3)
1011 = Shared Fault #4 (SFLT4)
1100 = Reserved
1101 = Independent Fault #2 (IFLT2)
1110 = Reserved
1111 = Independent Fault #4 (IFLT4)
bit 2 FLTPOL: Fault Polarity for PWM Generator #X bit
1 = The selected Fault source is low active
0 = The selected Fault source is high active
bit 1-0 FLTMOD<1:0>: Fault Mode for PWM Generator #x bits
00 = The selected Fault source forces PWMxH, PWMxL pins to FLTDAT values (latched condition)
01 = The selected Fault source forces PWMxH, PWMxL pins to FLTDAT values (cycle)
10 = Reserved
11 = Fault input is disabled
REGISTER 12-12: FCLCONx: PWM FAULT CURRENT-LIMIT CONTROL REGISTER (CONTINUED)