Datasheet
© 2006 Microchip Technology Inc. Preliminary DS70178C-page 117
dsPIC30F1010/202X
REGISTER 12-12: FCLCONx: PWM FAULT CURRENT-LIMIT CONTROL REGISTER
U-0 U-0 U-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
— — — CLSRC<3:0> CLPOL
bit 15 bit 8
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
CLMODE FLTSRC<3:0> FLTPOL FLTMOD<1:0>
bit 7 bit 0
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 15-13 Unimplemented: Read as ‘0’
bit 12-9 CLSRC<3:0>: Current-Limit Control Signal Source Select for PWM #X Generator bits
0000 = Analog Comparator #1
0001 = Analog Comparator #2
0010 = Analog Comparator #3
0011 = Analog Comparator #4
0100 = Reserved
0101 = Reserved
0110 = Reserved
0111 = Reserved
1000 = Shared Fault #1 (SFLT1)
1001 = Shared Fault #2 (SFLT2)
1020 = Shared Fault #3 (SFLT3)
1011 = Shared Fault #4 (SFLT4)
1100 = Reserved
1101 = Independent Fault #2 (IFLT2)
1110 = Reserved
1111 = Independent Fault #4 (IFLT4)
bit 8 CLPOL: Current-Limit Polarity for PWM Generator #X bit
1 = The selected current-limit source is low active
0 = The selected current-limit source is high active
bit 7 CLMODE: Current-Limit Mode Enable for PWM Generator #X bit
1 = Current-limit function is enabled
0 = Current-limit function is disabled