Datasheet

© 2010 Microchip Technology Inc. DS70139G-page 199
dsPIC30F2011/2012/3012/3013
APPENDIX A: REVISION HISTORY
Revision D (August 2006)
Previous versions of this data sheet contained
Advance or Preliminary Information. They were
distributed with incomplete characterization data.
This revision reflects these updates:
Supported I
2
C Slave Addresses
(see Table 14-1)
ADC Conversion Clock selection to allow
200 kHz sampling rate (see Section 16.0 “12-bit
Analog-to-Digital Converter (ADC) Module”)
Operating Current (I
DD) Specifications
(see Table 20-5)
Idle Current (I
IDLE) Specifications
(see Table 20-6)
Power-Down Current (I
PD) Specifications
(see Table 20-7)
I/O pin Input Specifications
(see Table 20-8)
BOR voltage limits
(see Table 20-11)
Watchdog Timer time-out limits
(see Table 20-21)
Revision E (December 2006)
This revision includes updates to the packaging
diagrams.
Revision F (May 2008)
This revision reflects these updates:
Added FUSE Configuration Register (FICD)
details (see Section 17.7 “Device Configuration
Registers” and Table 17-8)
Added Note 2 to Device Configuration Registers
table (Table 17-8)
Updated Bit 10 in the UART2 Register Map (see
Table 15-2). This bit is unimplemented.
Electrical Specifications:
- Resolved TBD values for parameters DO10,
DO16, DO20, and DO26 (see Ta ble 20 -9)
- 10-bit High-Speed ADC t
PDU timing
parameter (time to stabilize) has been
updated from 20 µs typical to 20 µs maximum
(see Table 20-37)
- Parameter OS65 (Internal RC Accuracy) has
been expanded to reflect multiple Min and
Max values for different temperatures (see
Table 20-19)
- Parameter DC12 (RAM Data Retention
Voltage) has been updated to include a Min
value (see Table 20-4)
- Parameter D134 (Erase/Write Cycle Time)
has been updated to include Min and Max
values and the Typ value has been removed
(see Table 20-12)
- Removed parameters OS62 (Internal FRC
Jitter) and OS64 (Internal FRC Drift) and
Note 2 from AC Characteristics (see
Table 20-18)
- Parameter OS63 (Internal FRC Accuracy)
has been expanded to reflect multiple Min
and Max values for different temperatures
(see Table 20-18)
- Updated Min and Max values and Conditions
for parameter SY11 and updated Min, Typ,
and Max values and Conditions for
parameter SY20 (see Table 20-21)
Additional minor corrections throughout the
document