Datasheet
dsPIC30F2011/2012/3012/3013
DS70139G-page 158 © 2010 Microchip Technology Inc.
FIGURE 20-2: BROWN-OUT RESET CHARACTERISTICS
TABLE 20-11: ELECTRICAL CHARACTERISTICS: BOR
DC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Symbol Characteristic Min Typ
(1)
Max Units Conditions
BO10 V
BOR BOR Voltage
(2)
on
VDD transition high to
low
BORV = 11
(3)
— — — V Not in operating
range
BORV = 10 2.6 — 2.71 V
BORV = 01 4.1 — 4.4 V
BORV = 00 4.58 — 4.73 V
BO15 V
BHYS —5—mV
Note 1: Data in “Typ” column is at 5V, 25°C unless otherwise stated. Parameters are for design guidance only and
are not tested.
2: These parameters are characterized but not tested in manufacturing.
3: 11 values not in usable operating range.
BO10
RESET (due to BOR)
VDD
(Device in Brown-out Reset)
(Device not in Brown-out Reset)
Power-Up Time-out
BO15