Datasheet

dsPIC30F2010
DS70118J-page 184 © 2011 Microchip Technology Inc.
TABLE 22-39: 10-BIT HIGH-SPEED A/D CONVERSION TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.7V to 5.5V
(unless otherwise stated)
Operating temperature -40°C TA +85°C for Industrial
-40°C T
A +125°C for Extended
Param
No.
Symbol Characteristic Min. Typ Max. Units Conditions
Clock Parameters
AD50 T
AD A/D Clock Period 84 ns See Table 18-1
(1)
AD51 tRC A/D Internal RC Oscillator Period 700 900 1100 ns
Conversion Rate
AD55 t
CONV Conversion Time 12 TAD ——
AD56 F
CNV Throughput Rate 1.0 Msps See Table 18-1
(1)
AD57 TSAMP Sample Time 1 TAD See Table 18-1
(1)
Timing Parameters
AD60 t
PCS Conversion Start from Sample
Trigger
1.0 TAD —ns
AD61 tPSS Sample Start from Setting
Sample (SAMP) Bit
0.5 TAD 1.5 TAD ns
AD62 tCSS Conversion Completion to
Sample Start (ASAM = 1)
0.5 TAD —ns
AD63 t
DPU
(2)
Time to Stabilize Analog Stage
from A/D Off to A/D On
——20μs—
Note 1: Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity
performance, especially at elevated temperatures.
2: t
DPU is the time required for the ADC module to stabilize when it is turned on (ADCON1<ADON> = 1).