6.4 DEVICE PROGRAMMING
Load the sample application program for the dsPIC30F3010 using this process:
1. Plug the RJ11 (telephone) cable from the MPLAB ICD 2 into the ICD header (J1).
Make sure the USB cable from the MPLAB ICD 2 is connected to your PC.
2. Start MPLAB IDE.
3. Open the dsPIC30F3010 sample project (
File>Open Workspace
)
from
path/dsPICDEM 2 Development Kit/Example Soft-
ware/30F3010/Demo.mcw.
4. Build the sample project in MPLAB IDE (
Project>Build All)
.
5. On the dsPICDEM™ 2 board set all positions on switch S4 to off. Then set switch
S2 to M ALL. The MPLAB ICD 2 is now connected to the PGC and PGD pins on
the dsPIC30F3010.
6. Download the sample application (
Programmer>Program
). The Output window
(Figure 6-2) displays the status as the download occurs and indicates when the
programming has succeeded.
FIGURE 6-2: PROGRAMMING THE dsPIC30F3010 DEVICE
7. Disconnect the MPLAB ICD 2 cable from the ICD header. The program is now
ready to run (see Section 6.5 “Observing the Sample Application”).
Note: For detailed information and procedures on using the MPLAB IDE and ICD